Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13633617

- Product Categories
- Friendly Links
Information Name: | Industrial cooling water circulating cold water system |
Published: | 2015-04-10 |
Validity: | 360 |
Specifications: | SJA-25 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Industrial cooling water circulating cold water systems SJW-10HP cooling water circulating cold water systems SJA-5HP air-cooled cold water system, "buy genuine - election Mountain Well" warmly welcome new and old customers choose Shanjing brand SJW cooling water circulating series of cooling circulating water industry cold water system, SJA series air-cooled air-cooled industrial cold water systems. The Company solemn promise: All of the original parts from the original manufacturer of new and imported, if users find I use second-hand compressors and other used parts of shoddy products. To "buy a paternity ten" to accompany the user taste. Industrial cooling water circulating cold water system which as the name implies: industrial cold water machine, industrial ice machines, industrial cold water systems, industrial chillers, industrial chillers, because this device is widely used, the reason for their name is different. Industrial cold water system is an industrial equipment section for circulating liquid cooling rapidly to improve production efficiency of cold water facilities. Liquid flows through an evaporator of liquid industrial cold water cooling systems needed to reach the goal. Compressed industrial cooler cycle including compression chillers four main components (compressor, evaporator, condenser, filter drier, thermal expansion valve), which has played a most important part of the process of cold water in the cold water. Use of multiple compressors in parallel, each compressor comes with a separate cold water circuits, namely evaporators, condensers are completely independent; all compressors by unified microcomputer control system, one by one open, shut, never with each other do not interfere with each other, with nine wells brand all imported genuine original production, the single failure rate is very low, the above reasons, you can ensure that the series has a highly stable machine performance, the first choice in many years of continuous operation. Single-stage refrigeration cycle single stage chiller is used widely in the refrigerator for a class, it can be applied aspects of ice, air conditioning, refrigeration and industrial food production processes. Single-stage refrigeration cycle refers to the refrigerant in the cooling system have been compressed, condensation, throttling, four evaporation process, will complete the single stage chiller cycle, which reached a refrigeration purposes. Refrigeration system evaporator, single-stage compressor, oil separator, condenser, ammonia storage device, the ammonia liquid separator, throttle and other ancillary equipment, etc., with each other through a pipe coupled in the closed system. Wherein, the evaporator cooling capacity is a conveying device, the heat absorbed by the cooling body refrigeration liquid refrigerant after evaporation; compressor is the heart of the system, plays a suction, compression, transport refrigerant vapor action; oil separator for sedimentation compressed refrigerant vapor separated in the oil; condenser compressor discharge temperature of the refrigerant vapor is condensed into a saturated liquid; ammonia storage device for storing the refrigerant condensed in the condenser ammonia solution, adjusted between the condenser and the evaporator supply and demand of the refrigerant liquid ammonia; ammonia liquid separator systems for liquid ammonia gravity important ancillary equipment; throttle the refrigerant from the throttling effect while controlling and regulating the flow of refrigerant into the evaporator liquid and the system is divided into high side and low side of the two-part two-stage refrigeration cycle system, dual-stage refrigeration cycle is developed on the basis of a single-stage refrigeration cycle, the compression process is divided into two phases, the refrigerant vapor from the evaporator first into the low to mid-level cylinder compression pressure, through the middle of the cylinder to cool down before entering the high pressure stage, compressed to the condensing pressure into the condenser. General evaporation temperature at -25 ℃ ~ -50 ℃, should adopt a two-stage compressor refrigeration. Refrigeration system evaporator, two-stage compressor, an oil separator, a condenser, an intercooler, ammonia storage device, the ammonia liquid separator, throttle and other ancillary equipment, etc., with each other through a pipe coupled in the closed system . Among them, the use of a small amount of liquid intercooler refrigerant absorbs heat of vaporization at the intermediate pressure, superheated steam discharged from the low pressure stage is cooled to reduce the high pressure stage of the suction temperature, but also the high-pressure liquid refrigerant is cooled. Compressor refrigeration system basically consists of: compressor refrigeration system is the whole core component refrigerant is compressed source of power. Its role is to input electrical energy into mechanical energy, the compressed refrigerant cycle. Evaporator: The evaporator is relying evaporator refrigerant liquid (actually boiling) to be absorbed by the cooling medium heat exchanger member. It functions in a refrigeration system is to absorb heat (or cold output). In order to ensure the evaporation process can be long-lasting and stable, we must continue with the refrigeration compressor pumped the gas evaporation, evaporation to maintain a certain pressure. Condenser: a condenser in the refrigeration process and play the output of heat to the refrigerant condensed effect. After the refrigerant discharged from the compressor high pressure superheated vapor into the condenser, which in all of the heat absorbed by the working process, including the refrigerant compressor and the evaporator and heat is absorbed in the pipe are transmitted to the surrounding medium by the cooling water or fans away; refrigerant high pressure superheated steam condenses back into a liquid. (Depending on the cooling medium and the cooling mode, the condenser can be divided into three categories: shell and tube condenser, finned condenser, evaporator and condenser.) Thermal expansion valve: thermal expansion valve flow both in the refrigeration system valve, and refrigeration equipment throttle, which is installed between the filter drier and evaporator refrigeration equipment, its temperature package is wrapped in the outlet of the evaporator. Its main role is to make high-pressure refrigerant liquid at room temperature, throttle down when passing through the thermal expansion valve, into a low-pressure refrigerant wet steam (mostly liquid, a small part of the steam) into the evaporator, vaporized in the evaporator endotherm, while the cold water to achieve the purpose of cooling. Dry filter: In the refrigeration cycle must prevent moisture and dirt (oil, iron, copper scrap) from entering, the main source of water is the newly added trace moisture refrigerant and oil contained in the system or due to maintenance When the air is brought into the water. If the system does not preclude clean water, when the refrigerant throttle (thermostatic expansion valve or capillary) through, because sometimes downward pressure and temperature of water will solidify into ice, making obstruction, affecting the normal operation of the refrigeration unit. Therefore, in the refrigeration system must be installed in dry filter. Reservoir: accumulator installed after the condenser, the condenser and the outlet tube is in direct communication. Refrigerant liquid flows into the condenser should be unimpeded within the reservoir, so that you can take full advantage of the condenser cooling area. On the other hand, when the heat load changes of the evaporator, the refrigerant liquid required amount also changes, then, the reservoir will act as adjustment and storage of the refrigerant. Cold water system for small devices often do not install the reservoir, but the use of the condenser to adjust and store refrigerant. Refrigerant: Most industrial cold water systems used in modern industry are used as a refrigerant R22 or R12. The refrigerant is cold refrigerant flow system, its main role is to carry heat, and realize endothermic and exothermic changes in the state. Well-card works industrial cold water system according to the principle of the cold water system, low-temperature and low-pressure liquid refrigerant inside the evaporator and the gaseous heat exchange medium surrounding the evaporator absorbs heat, is evaporated into low temperature and pressure, the evaporation temperature of the refrigerant during the constant volume changes, the low-temperature low-pressure gas refrigerant into the compressor, compressed by the compressor, is compressed to high temperature and pressure gas into the condenser, the condenser in heat exchange with the interior of the medium, part of the heat of high temperature and pressure of gaseous is absorbing medium, medium temperature, the high temperature medium is cooling water / cooling fan exits the condenser, the refrigerant becomes high temperature and high pressure condenser the exothermic liquid effluent, after the dry filter and dried filtered, flows into the expansion valve is throttled down pressure, throttle rapid cooling process, the liquid refrigerant into a low-temperature low-pressure refrigerant into the evaporator and then heat the evaporator, in order to achieve the whole process of cold water systems; Well-card industry classification system 1. cold water cold water system in the refrigeration process. Freons the temperature within the evaporator sucked into the condenser, the high temperature part inside the condenser which requires cooling, such as the use of the circulating cooling water to the high-temperature exhaust heat, named for the cooling water circulating cold water system. 2. cold water system in the refrigeration process. Cold water system in the refrigeration process. Lengmei the temperature in the evaporator condenser intake, high temperature components within its condenser cooling needs, such as the use of high-temperature exhaust fan to dissipate heat, named for the air-cooled cold water systems. Industrial cold water circulating cooling water systems, air-cooled two kinds of cooling water circulating cooling effect is good, but need cooling water, air-cooled without cooling water, flexible, suitable for dryland or require the use of mobile applications. Industrial cold working medium is the cooling water system of the system responsible for the task of transferring heat refrigerant, common refrigerants are: Freon, ammonia, lithium bromide, chloride, etc., wherein the flon its vaporization temperature and chemical formula Different fluorine 11 (R-11), fluorine 12 (R-12), fluorine 13 (R-13), fluorine 21 (R-21), fluorine 22 (R-22), fluorine-113 (R-113), fluoro-114 (R-114), fluoro-142 (R-142) and many other. Respectively for the refrigerant low pressure (condensing pressure less than 0.3-0.3MPa) high temperature (evaporation temperature is greater than 0 ℃), medium pressure (condensing pressure 1-2MPa) the temperature (evaporation temperature 0--50 ℃) and high pressure (condensing pressure greater than 2MPa) low temperature (evaporation temperature of less than -50 ℃) refrigeration system cold water systems major industries: rubber products, metals, chemicals, electronics, food preservation, laser engraving, vacuum coating, ultrasonic cleaning professionals, hotels, office buildings for plastic , heating and cooling bath, medical storage, laser technology, welding, plastic molding, injection molding, extrusion, blow molding, thermoforming, mechanical cutting plus non-machining, casting, surface treatment, plating, oxidation, electrophoresis, medical equipment, electronics industry-specific, circuit board manufacturing, electronics Ruipian manufacturing, chemical, paper, pharmaceutical, food, aluminum, aluminum, glass, coated glass production and processing ,, jewelry, fur processing, ink production, textile, printing and other industries . Well-range brand industrial use cold water system 1. cold water injection cooling water circulation system of industrial cold water systems used in plastics processing machinery cooling circulating water cooling, can greatly improve the surface finish of plastic products, plastic products, reduce surface pattern marks and internal stress so that the product does not shrink, no deformation, easy stripping of plastic products, accelerate product shape, thereby greatly enhancing the production efficiency of plastic molding machines. Plastic pellets melted by heating the water injected into the cooling cycle, after condensation, mold ejection of the molded plastic parts, there is a continuous production process required for the cooling water circulation for cooling, in order to shorten the plastic coagulation time and improve the dimensional accuracy of the workpiece, forming quality surface quality. Cold water temperature requirements: 6 ~ 18 ℃ cold water temperature requirements: ± 2K or ± 0.5K. Industrial freezing cold water systems group injection molding machine and the amount of capacity, the greater the amount of injection, the required capacity is also a large plastic container of cold water (blowing) and packaging film production is more inseparable from the cold water system (ice machine): plastic containers in the production process if not timely cooling setting produced container is not full color is not bright, uneven thickness can not be formed even result in a lower product quality. The production of packaging films such as no cold water (air) cooling the molding can not be to produce qualified products. Such as the use of cold water system (ice machine) to provide cold water (wind) to cool not only can greatly improve the quality of products but also to improve production efficiency of injection molding machines with clamping force is usually nominal, which needs to be converted into ounces tonnage, conversion relationship but not correspond tonnage and ounces, the following table is only under normal circumstances, and have some down deviation 2. anodized cold water systems in the electroplating industry oxidation, electrophoresis industry, industrial cold water systems help to metal and non-metallic ions stabilized so that the metal ion plating quickly attached pieces, pieces oxidation, electrophoresis pieces, not only increase density and smooth, and reduce the number of plating production in electroplating, plating solution in the plating is not reflected in segment generate heat, so that the plating solution temperature gradually increased, when the temperature is higher than the plating solution process requirements, the output of the finished appearance of coating plating firmness, uniformity, flatness and have a greater impact on the appearance of the finish. The freeze selection system with cold water (chiller) provided in the production process of the electronic components which need to make the coupling assembly at a specific temperature or cooling, functional electronic components of the control parameters of brilliance in the default state. Heated water to cool and connect the plating solution, plating production process will greatly improve production efficiency and 3. Chemical cold water system circuit board manufacturing process and when the surface of copper corrosion by the copper plate attached to the heat, so that the temperature rise of the pool of corrosion, affect the quality of the circuit board, the use of industrial cold water temperature corrosion protection system to the pool. Circuit board cleaning: industrial cold water system can reduce the temperature of the cleaning agent, condensing the gaseous cleaning agent, effective to prevent evaporation of the cleaning agent. Electronic components, circuit board cleaning, the cleaning agent will evaporate into the air, with the inner tube through the cold water / refrigerant through the tubing / titanium tube so that the cleaning agent is condensed, the cleaning tank at a moderate temperature to reduce volatile cleaning agent. 4. Laser cold water system industrial cold water system is mainly used in laser marking machine, laser engraving machine, laser welding machines, laser inkjet printer, laser cutting machine, laser processing equipment, etc., which can precisely control the temperature required for laser equipment , thus ensuring the normal operation of the laser device. Product Features: The United States imported brand Copeland compressor, built-in security protection, low noise, power and durability to increase the life of the equipment. Efficient fin condenser, high heat transfer efficiency, plus efficient external rotor fan, without connecting the advantages of cooling tower systems. Using commercially pure titanium and open stainless steel tank evaporator, built-water protection and other devices, in order to facilitate customers with water and cleaning maintenance. Stainless steel multi-stage pump and water pipes, water can be prevented to produce a solid and other metallic impurities in the transportation process. Laser laser (laser) system generating source, beam controller and cabinet may require additional cooling. Of cold water temperature requirements are usually between 15 ... 22 ℃, the precision requirements for cold water usually ± 1K or ± 2K. Some of the equipment may be required ± 0.5K, another part of the equipment for freezing water conductivity, corrosion resistance, etc. There are certain requirements. Therefore, the water quality is very high, stainless steel pipe or PVC pipe. Laser systems for special applications, industrial cold water can be designed to meet different system requirements 5. Reactor cold water reactor system dedicated industrial cold water systems Features: imported cryogenic compressors, automatic computer control , a cold water pipe material for "Titanium", high-performance heat exchangers, but also with international brands accessories, temperature control range of -80 ℃ ~ 20 ℃, widely used in fine chemicals, corn deep processing (starch), pharmacy, medicine store etc. 6.UV curing cold water systems: Features: stepless dimming + water cooling + metal halide = + low + high efficiency energy saving lamps indoor water-cooled quartz glass + install air-cooled heat exhaust heat lamp underneath, effectively reduce the illuminated surface temperature, protect dry goods will not heat deformation, to extend lamp life; SJW industrial water cooling machine for: offset, gravure, flexo printing machine, polishing coating machine printing equipment at home and abroad . Offset such as: Germany MAN Roland, Heidelberg, KBA, Komori, Ryobi, Mitsubishi, Sakurai, North persons. Gravure printing machine such as: Swiss Bobst, Italy Cerutti, Xi'an black one, Zhongshan Ostersund. The ultrasonic professional cold water systems: The study shows that: the role of ultrasound in the liquid, the liquid in each bubble burst will produce a great shock wave energy, equivalent to instantly generate a high temperature of several hundred degrees and up to thousands of atmospheres, which phenomenon is called "cavitation", ultrasonic cleaning with a shock wave is generated by the liquid bubble burst to achieve the role of the inner and outer cleaning and scouring of the workpiece surface. Second ultrasonic propagation in liquid, the liquid, together with the cleaning tank at ultrasonic frequency vibrations, liquid cleaning tank and has its own natural frequency of vibration, the vibration frequency of the acoustic frequency, so people can hear the hum of water cleaning The most suitable cleaning fluid temperature is 40-60 ℃, especially if the effect of the cleaning liquid temperature difference at low altitude when it's cold, the cleaning effect is poor. Thus some washing machines wash tank outside the heating wire wound on the heating temperature control, when the temperature rises cavitation prone, so the cleaning effect is better. When the temperature continues to rise, increasing the gas pressure within the vacuole, causing impact sound pressure decreased, reflecting the synergistic action of these two factors. Classics on the final factor, mountain wells brand industrial cold water systems can reduce the temperature of the cleaning agent, condensing the gaseous cleaning agents, cleaning agents effectively prevent evaporation vacuum coating cold water systems 8. A. vacuum of the film: IF vacuum coating machines are generally equipped with a Taiwan industrial cold water systems as a coating machine (mostly cylindrical target) cooling equipment IF equipment cooling water must be added, because it is a high frequency current is large. Current from flowing in a conductor skin effect, the charge will be gathered in the conductance has a surface area, such that the conductance heat pipe do so using the hole conductor intermediate water cooling. Surface treatment watch parts, jewelry, jewelry, hardware, plumbing equipment, jewelry, plastic products, sanitary ware, locks, lighting, tableware handle a variety of products such as: B. ion plating. Ionization source in the initial work to be heated up and running when you need cooling, cooling system failure will result in damage to the ionization source. Cooling water must be cooled to the cooling channels of the source from within the ionization source with a high pressure water pump. C. Coated Glass: often require large amounts of cold units, usually more than one screw-type cold water systems in combination. Coating production line to be heated before starting in order to achieve a certain temperature, due to self-generated heat is required chilled water cooling to maintain low temperature after starting. Well-brand industrial cold water systems using imported configuration, automatic computer controller that can control the temperature of the fine coating machine, according to customer requirements for different consumer and production of high precision cold device complies customer requirements. In order to ensure high quality plating. 9. Hydraulic coagulation dedicated cold water systems are mostly bulky concrete. Need to reduce the heat of hydration of concrete. Reduce the temperature of the concrete pouring is a very effective means. By industrial cold water system equipment can be made out of the water temperature is low, to reduce the temperature of the concrete of the machine. Concrete temperature can drop below 20 degrees 10. Glass cool special cold water systems will generally glass heated to high temperatures and then quickly cooling, the cooling water temperature is not too high, otherwise it will affect the quality of steel. Provide cooling with cold water with industrial cold water system, the water temperature does not love the other effects of ambient temperature, to ensure product quality. Features: 1, compressor selection of international brand "Daikin Series", "Sanyo Series", "Panasonic" series, built-in security protection, low noise, power and durability. 2, the electrical part of the international brand "LG" products, to ensure that the machine is stable, long life. 3, imported from Italy and Taiwan famous factory water pump, high flow, high efficiency, long-lasting and durable. 4, equipped with imported precision digital display temperature controller can accurately control the temperature of ± 1 ℃, the set temperature range 3 ℃ -50 ℃. 5, full of thick stainless steel water tank evaporator, built-in automatic replenishment and other devices quick and easy cleaning and maintenance. 6. Industrial cold water systems group condenser tube type, sleeve threaded brass, reasonable design, good effect of heat transfer; heat cold air-cooled unit row, coupled with the ranks of brass fins composed of manufacturing using secondary flanging fins machinery rose tube heat exchanger technology and advanced production line to ensure high quality and efficiency. 7, electrostatic spray shell, Europeanization design, elegant appearance board adopts the form of rapid disassembly, easy to use and maintain. All our equipment sales service: one year warranty and lifetime maintenance (except for man, wearing parts and force majeure) equipment maintenance customers received written notices, Guangdong province 36 hours in response to the scene maintenance, Guangdong province 72 small response scene maintenance. Cold water circulating cooling water system technical parameters Water-cooled chiller technical Parameters Model Model Refrigerati ng capacity refrigeration compressor Compressor Condenser Evaporator Evaporator Condenser water pump water pump Dimensions Shape dimension Net Net wei ght kcal / h kw kw hp L inch m3 / h inch m3 / h kw mpa (mm) (kg) SJW-01 2709 * 0.75 1 30 3/4 "1.2 3/4" 1.15 0.37 0.18 720 × 400 × 1100 110 SJW-02 5332 6.2 1.5 2 30 3 / 4 "1.2 3/4" 1.5 0.37 0.18 720 × 450 × 1100 118 SJW-03 8127 9.45 2.2 3 50 3/4 "1.8 3/4" 2.16 0.37 0.18 760 × 480 × 1050 130 SJW-04 10836 12.6 3 4 50 3/4 "2.6 3/4" 2.8 0.37 0.18 850 × 480 × 1180 150 SJW-05 13545 15.75 3.75 5 70 1 3 1 3.6 0.75 0.18 850 × 480 × 1180 160 SJW-06 16254 18.9 4.5 6 90 1 3.6 1 4.4 0.75 0.18 980 × 550 × 1180 220 SJW-08 21572 25.2 3 × 2 8 140 2 "5 2" 6 0.75 0.18 1200 × 620 × 1400 240 SJW-10 27090 31.5 7.5 10 160 2 "6 2" 7.2 1.5 0.18 1300 × 620 × 1400 310 SJW-12 32508 37.8 4.5 × 2 12 170 2 "7.5 2" 8.9 1.5 0.18 1300 × 620 × 1500 430 SJW-15 40635 47.25 5.5 × 2 15 200 2 "9 2" 11.3 1.5 0.18 1500 × 700 × 1600 480 SJW-20 54180 63 7.5 × 2 20 300 2 "12 2" 15 2.2 0.18 1600 × 800 × 1600 660 SJW-25 67725 78.75 9 × 2 25 300 2.5 "15 3" 19 2.2 0.18 1700 × 850 × 1600 740 SJW-30 81270 94.5 7.5 × 3 30 450 2.5 "18 3" 23 3 0.18 1900 × 900 × 1700 810 SJW-35 97524 113.4 9 × 3 35 500 2.5 "22 3" 27 3 0.18 1950 × 920 × 1700 890 SJW -40 108360 126 7.5 × 4 40 600 2.5 "25 3" 31.5 3.75 0.18 2100 × 1050 × 1800 980 SJW-45 119196 138.6 2 (7.5 + 9) 45 600 3 "28 3" 35 3.75 0.18 2200 × 1050 × 1800 1100 SJW-50 135450 157.5 7.5 × 5 50 700 3 "32 3" 39 3.75 0.18 2300 × 1200 × 1800 1200 SJW-60 162540 189 9 × 5 60 800 3 "40 3" 43 3.75 0.18 2400 × 1300 × 1800 1400 SJW- 40S 113520 132 30 40 / 2.5 26 2.5 30 / / 2000 × 650 × 1600 920 SJW-50S 141900 165 37.5 50/3 "30 3" 38 / / 2000 × 650 × 1650 1150 SJW-60S 170280 198 45 60/4 " 36 4 "46 / / 2500 × 650 × 1650 1240 SJW-70S 198660 231 52.5 70/4" 42 4 "54 / / 2550 × 650 × 1650 1290 SJW-80S 227040 264 60 80/4" 48 4 "62 / / 2800 × 650 × 1800 1330 SJW-90S 255420 297 67.5 90/4 "56 4" 70 / / 2800 × 650 × 1800 1390 SJW-100S 283800 330 75 100/4 "62 4" 78 / / 3200 × 650 × 1800 1440 SJW-110S 312180 263 82.5 110/4 "68 4" 86 / / 3300 × 800 × 1800 1500 SJW-120S 340560 396 90 120/4 "74 4" 94 / / 3500 × 800 × 1800 1530 SJW-130S 368940 429 97.5 130/4 "80 4" 102 / / 3500 × 800 × 1800 1580 SJW-140S 397320 462 105 140 / 4.5 "86 4.5" 110 / / 3600 × 800 × 1900 1620 SJW-150S 425700 495 112 150 / 4.5 "92 4.5 "118 / / 3600 × 800 × 1800 1660 SJW-160S 454080 528 120 160 / 4.5" 106 4.5 "126 / / 3900 × 1100 × 1600 1710 SJW-180S 540840 594 135 180 / 4.5" 112 4.5 "134 / / 4100 × 1100 × 1600 1830 SJW-200S 567600 600 150 200 / 4.5 "118 4.5" 142 / / 4100 × 1400 × 1600 1910 Note: 1. Cold compressors: withstand the highest temperature of 45 ℃, the use of refrigerant R22. Refrigeration compressor: Support highest temperature 45 ℃, Refrigerant R22 for use 2. Screw cold water energy automatic control system set to 100% -75% -50% -25%. Screw water chillers energy automatic control for 100% -75% -50% -25%. 3. Evaporating into the water temperature 12 ℃, the evaporation temperature of water 7 ℃. Condensation temperature into the water 30 ℃, condensing temperature water 35 ℃. Evaporation temperature into the water 12 ℃, Evaporation temperature water 7 ℃, Cooling water temperature into 30, Cooling water temperature for 35. 4. CRW-15 ~ CRW-60 users can develop an open unit, the same type of performance parameters and cold water system cabinet unanimously .The user can formulate open type Cold water machine, performance and the Cold water machine consistent 5. The above parameters are subject to change without notice. The above parameters are subject to change without prior notice. |
Admin>>>
You are the 18187 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Shan Well Machinery Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 18187 visitor
Copyright © GuangDong ICP No. 10089450, Shenzhen Shan Well Machinery Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility